      Appendix 10G Emergency Response Procedures for Iodine-125 Spill
    
  
          
  - Ensure no one is in the area where the spill is.
- Wear suitable respiratory protection equipment, SCBA in this case, before entering the contaminated area.
- Use a GM or NaI for monitoring of the spill.
- Cover the spill with absorbent paper.
- Cover the paper with alkaline sodium thiosulfate (0.1 M NaI, 0.1 M NaOH, 0.1 M Na2S2O3).  Avoid contacting the spill with acid.
- Wait for 10 minutes before wastes clean up.  Contain all wastes in a tightly sealed bag.
- In the event of suspected iodine take, a urine assay must be conducted within 24 hr of the suspected exposure.  A coarse evaluation of iodine intake can be achieved by placing a GM or NaI probe to the neck of the individual suspected of iodine intake.  Noticeable counts indicate a potential uptake of iodine.
- Should intake exceed the legal limit allowed, the case has to be reported Radiation Board for further investigation.